Baxter I.V. Catheter Extension Set With Male Luer Lock Adapter non DEHP is an intravenous extension set with a male luer lock adapter to ensure a proper seal to deliver medication or fluids to the body. This extension set makes it easier to place medicines in patients as needed and has a primary volume of .5 milliliters.
CONTINU FLO Solution Set with 0.22 micron downstream high pressure extended life filter and 3 INTERLINK injection sites 6 18 and 82 from male Luer lock adapter. S . Approx. drops per mL 10. Approx. overall length 104 2.6 m . S indicates set has tubing that is compatible with the COLLEAGUE Series Volumetric Infusion Pumps and FLO GARD 6201 and 6301 Series
Oct 23 2008 Thu 10/23/200812 31. #1. Clinical Ninja. Positive PressureThe Truth I am in a continuous state of disbelief surrounding the various experts that are constantly negating the true benefits of positive pressure connectors. I am a seasoned clinician researcher and have been following this topic for many years.
1 Secondary Medication set Baxter Clearlink male luer lock connector 10drop/mL 37″ tube w/ hanger LF sterile 1 IV Catheter Extension Set 7″ tubing male luer lock 1 needleless port 0.2 ml priming volume. Primary Administration Set Clearlink 10dr/mL drip rate 113 tube 2 port Primary Administration Set PlumSet 15 Drop / mL
Needleless connectors have been introduced into clinical practice to eliminate needlestick injuries and prevent catheter related bloodstream infections. This is the procedure for changing the needleless connector cap on peripheral and central venous catheter CVC .
The Baxter InterLink St. Paul Medical Key Lok Braun SafSite and Becton Dickinson heparin lock were compared. Fifty of each were studied. Each system was connected to a
Jul 06 2011 26. Product. Baxter Interlink System Non DEHP I.V. Catheter Extension Set 6.6u001d 17 cm Volume 0.8 mL Injection Site Male Luer Lock Adapter an Rx sterile single use nonpyrogenic fluid pathway 200 sets per case Baxter Healthcare Corporation Deerfield IL 60015 USA product code 2N3375. Intended use For the administration of drugs
2C6757 6515 01 425 1246 Administration set Infusion Pump Special Features Interlink needleless blood administration set Y type with 80 filter one injection site and luer lock adapter Part Name Assigned BY Controlling Agency Administration set infusion pump interlink needleless 1G026
overall hospital costs. METHODS A needleless intravenous access system Interlink i.v. Access System Baxter Healthcare Corp. Parenterals Division Deerfield Ill. was introduced. Effectiveness and cost benefit of this system were analyzed by comparing needlestick injuries and their associated costs as well as costs of relevant
Interlink Baxter Blunt plastic cannula for IV connection There are several studies of needleless intravenous devices showing large reductions in injuries associated with accessing IV lines 70–80 . Some of the best quality of evidence is for blunt suture needles.
INTERLINK system replaces steel needles with blunt plastic cannula and split septum access ports. Get In Touch. Discover what Baxter s comprehensive IV Access portfolio can do for your organization. Contact Us. Rx Only. For the safe and proper use of the devices mentioned herein please refer to the appropriate Instructions for Use or Operator
Baxter Country of Origin Puerto Rico Administration Method Gravity Application Y Type Blood Solution Set Connection Type Male Luer Lock Connector Drip Rate 10 Drops / mL Drip Rate Filter Size 170 to 260 Micron Filter Material PVC Number of Ports 1 Port Port Type Needleless Injection Port Interlink Injection Site Priming
Baxter Y Type Blood/Solution Set with Standard Blood Filter 170 to 260 Micron INTERLINK Injection Site 10 drops/mL 114 Inch is compatible with COLLEAGUE and FLO Gard series volumetric infusion pumps. This IV Set is designed with a Y type tubing with a sterile fluid path for safe blood transfusions. The micron blood filter effectively removed blood clots and aggregates.
Baxter CLEARLINK Needleless I.V. Admin Sets by Baxter Healthcare Accessories 1 Questions 1 Similar Products Clearlink combines standard set technology with unique design characteristics including a non latex clear polycarbonate housing a large easy to swab injection surface and a silicone based double design.
INTERLINK Baxter Negative 0.2 mL No luer blunt cannula. An NC is a device that allows for safe needleless connection to VADs while reducing the risks of extraluminal infection
Class 2 Device Recall Baxter Interlink System Buretrol . Accessdata.fda.gov DA 22 PA 34 MOZ Rank 80. Baxter Interlink System Buretrol Solution Set 83 2.1 m 150 mL Burette Drip Chamber Filter Valve 2 Injection Sites Male Luer Lock Adapter Large Bore 4 Way Stopcock with Rotating Male Luer Lock Extension Set 38 97 cm Vol
Needless Connectors for IV Catheters have a translucent or opaque external housing. A clear connector like the CLEARLINK Luer Activated Valve offers an advantage giving a view at a glance if residual blood or other matter is left behind. This design is also referred to as a Luer lock IV connector. The Luer housing slips in and rotates for a firm connection.
were Clearlink7 Baxter SmartSite8 12 Alaris Medical Systems and CLAVE13 ICU Medical . The simple needleless connectors were the standard capped connector 6 three way stopcock with cap attached 7 8 and Interlink split septum10 12 Baxter .
1991 Our INTERLINK IV Access System launched introducing the first needleless system for IV therapy. 1994 HOMECHOICE our automated peritoneal dialysis APD system launched. We also opened a plant in Singapore to make peritoneal dialysis solutions for the Asian market.
BD Interlink Blunt Plastic Cannula. The BD Blunt Plastic Cannula is a truly universal cannula and can be used with all types of split septum IV injection sites and vials designed for needleless access. It provides simplified access to the Interlink injection site with smoother insertion reduced penetration force and greater fluid dispersion.
Universal Compatibility with Baxter Interlink Abbott LifeShield and McGaw SafeLine injection sites as well as vials designed for needleless access Condition New New Items which are brand new and ship directly from the manufacturer or a manufacturer approved vendor or distributor with standard accessories warranty and support where applicable.
Tim Murawski started his medical device sale career at Baxter Healthcare’s IV System department when he used to sell their innovative interlink Needleless IV merchandise. Tim Murawski realized that he wanted to be in the medical field to establish his sales career.
Apr 15 2002 In addition as long as Coram commits to purchase 90 of its needleless requirements from Baxter Baxter shall provide MVI 12 2A9005 at. If Coram exits this portion of the Contract the MVI 12 2A9005 price shall be adjusted to plus any applicable price increases after the first twelve months of this Contract.
The Baxter INTERLINK System is a proven performer for reducing needlestick injuries during IV access. The Baxter INTERLINK Injection Site is the key component behind the INTERLINK family of IV access products. Male Luer Lock Adapter. Non DEHP.
Baxter Interlink System Non DEHP I.V. Catheter Extension Set product code 2N3384 An Rx sterile nonpyrogenic fluid pathway 9.0 0.5 mL Vol. with injection site and male Luer Lock adapter with Retractable Collar Baxter Healthcare Corporation Deerfield IL 60015 U.S.A. Code Information product code 2N3384 lot UR255125 Recalling Firm/